{"product_id":"hot-sales-usb-1747-cp3-usb-adapter-for-ab-slc-5-03-5-04-5-05-plc-free-shipping","title":"HOT SALES!  USB-1747-CP3:USB adapter for AB SLC 5\/03,5\/04,5\/05 PLC, Fast Shipping","description":"\u003cp\u003e \u003cimg alt=\"aeProduct.getSubject()\" height=\"500\" src=\"http:\/\/g04.a.alicdn.com\/kf\/HTB1NvU7JpXXXXX1XFXXq6xXFXXX8\/201062613\/HTB1NvU7JpXXXXX1XFXXq6xXFXXX8.jpg\" width=\"1000\" title=\"aeProduct.getSubject()\"\u003e\u003c\/p\u003e \n\u003cp\u003e \u003cspan style=\"font-size: 18px;\"\u003e\u003cspan style=\"color: #ff0000;\"\u003eUSB interface ALLEN BRADLEY SLC 5\/03,5\/04,5\/05 PLC programming adapter\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e \n\u003cp style=\"text-align: center;\"\u003e \u003cimg alt=\"aeProduct.getSubject()\" src=\"http:\/\/g01.a.alicdn.com\/kf\/HTB12nE2GXXXXXc3XXXXq6xXFXXXA\/201062613\/HTB12nE2GXXXXXc3XXXXq6xXFXXXA.jpg\" title=\"aeProduct.getSubject()\"\u003e\u003c\/p\u003e \n\u003cp\u003e Functions \u003c\/p\u003e \n\u003cp\u003e   \u003c\/p\u003e \n\u003cp\u003e \u003cspan style=\"color: #ffffff;\"\u003e\u003cspan style=\"background-color: #ff1234;\"\u003e1.\u003c\/span\u003e\u003c\/span\u003eSupport USB-1747-CP3 operating system: Windows2000\/XP (WinNT4\/95\/98\/Me\/DOS not included)  \u003c\/p\u003e \n\u003cp\u003e \u003cspan style=\"color: #ffffff;\"\u003e\u003cspan style=\"background-color: #ff1234;\"\u003e2.\u003c\/span\u003e\u003c\/span\u003esupport USB-1747-CP3 programming software version:RS Logix 500 and above  \u003c\/p\u003e \n\u003cp\u003e \u003cspan style=\"color: #ffffff;\"\u003e\u003cspan style=\"background-color: #ff1234;\"\u003e3.\u003c\/span\u003e\u003c\/span\u003efully compatible with USB 2.0 standard  \u003c\/p\u003e \n\u003cp\u003e \u003cspan style=\"color: #ffffff;\"\u003e\u003cspan style=\"background-color: #ff1234;\"\u003e4.\u003c\/span\u003e\u003c\/span\u003eUSB bus-powered, the current consumption of about 50 mA  \u003c\/p\u003e \n\u003cp\u003e \u003cspan style=\"color: #ffffff;\"\u003e\u003cspan style=\"background-color: #ff1234;\"\u003e5.\u003c\/span\u003e\u003c\/span\u003eeach PC only supports a USB cable programming  \u003c\/p\u003e \n\u003cp\u003e \u003cspan style=\"color: #ffffff;\"\u003e\u003cspan style=\"background-color: #ff1234;\"\u003e6.\u003c\/span\u003e\u003c\/span\u003etemperature: -20 ~ +75   \u003c\/p\u003e \n\u003cp\u003e \u003cspan style=\"color: #ffffff;\"\u003e\u003cspan style=\"background-color: #ff1234;\"\u003e7.\u003c\/span\u003e\u003c\/span\u003eCable length: three meters, colors: black \u003c\/p\u003e \n\u003cp\u003e \u003cbr\u003e System requirement \u003c\/p\u003e \n\u003cp\u003e   \u003c\/p\u003e \n\u003cp\u003e Please make sure your PC is IBM PC compatible and has the following system requirements before using the USB programming cable.  \u003c\/p\u003e \n\u003cp\u003e \u003cspan style=\"color: #ffffff;\"\u003e\u003cspan style=\"background-color: #ff1234;\"\u003e1.\u003c\/span\u003e\u003c\/span\u003eIntel is compatible with 586DX4-100MHz CPU or higher \u003c\/p\u003e \n\u003cp\u003e \u003cspan style=\"color: #ffffff;\"\u003e\u003cspan style=\"background-color: #ff1234;\"\u003e2.\u003c\/span\u003e\u003c\/span\u003eA standard USB port (4-pin A plug) \u003c\/p\u003e \n\u003cp\u003e \u003cspan style=\"color: #ffffff;\"\u003e\u003cspan style=\"background-color: #ff1234;\"\u003e3.\u003c\/span\u003e\u003c\/span\u003eOperating system is Windows2000 or Windows XP \u003c\/p\u003e \n\u003cp\u003e   \u003c\/p\u003e \n\u003cp\u003e \u003cbr\u003e The setting of driver procedure \u003c\/p\u003e \n\u003cp\u003e   \u003c\/p\u003e \n\u003cp\u003e Please set the driver procedure according to the following steps: \u003c\/p\u003e \n\u003cp\u003e 1. Turning on PC power that will connect the USB programming cable and make sure the USB port working well. \u003c\/p\u003e \n\u003cp\u003e 2. Put the USB programming cable into USB port and Windows will detect the device and help to add new hardware and jump to new device setting. Insert the driver CD and click “next” to continue, or select the driver on the hard disk. \u003c\/p\u003e \n\u003cp\u003e If Windows does not show “Found New Hardware Wizard”, please click “Universal Serial bus controllers” in the hardware list of device manager, and choose the USB device with question mark. Click the right key of mouse and operate to update driver procedure. \u003c\/p\u003e \n\u003cp\u003e   \u003c\/p\u003e \n\u003cp\u003e \u003cimg alt=\"aeProduct.getSubject()\" src=\"http:\/\/g01.a.alicdn.com\/kf\/HTB12nE2GXXXXXc3XXXXq6xXFXXXA\/201062613\/HTB12nE2GXXXXXc3XXXXq6xXFXXXA.jpg\" title=\"aeProduct.getSubject()\"\u003e\u003c\/p\u003e \n\u003cp\u003e If insert the driver CD,you should select the recommended item and click “Next” \u003c\/p\u003e \n\u003cp\u003e \u003cimg alt=\"aeProduct.getSubject()\" src=\"http:\/\/g02.a.alicdn.com\/kf\/HTB18mgWGXXXXXXIXpXXq6xXFXXXb\/201062613\/HTB18mgWGXXXXXXIXpXXq6xXFXXXb.jpg\" title=\"aeProduct.getSubject()\"\u003e\u003c\/p\u003e \n\u003cp\u003e If the driver is saved on the hard disk, you should select the second item and click “Next”. You can find the driver on the “WIN” folder. \u003c\/p\u003e \n\u003cp\u003e   \u003c\/p\u003e \n\u003cp\u003e \u003cimg alt=\"aeProduct.getSubject()\" src=\"http:\/\/g01.a.alicdn.com\/kf\/HTB18A3ZGXXXXXbBXpXXq6xXFXXXZ\/201062613\/HTB18A3ZGXXXXXbBXpXXq6xXFXXXZ.jpg\" title=\"aeProduct.getSubject()\"\u003e\u003c\/p\u003e \n\u003cp\u003e 3. Windows will detect the setting information, and load the driver to install. \u003c\/p\u003e \n\u003cp\u003e   \u003c\/p\u003e \n\u003cp\u003e 4. Continue to set up, copy the driver procedure files to your hard disk by Windows. \u003c\/p\u003e \n\u003cp\u003e   \u003c\/p\u003e \n\u003cp\u003e \u003cimg alt=\"aeProduct.getSubject()\" src=\"http:\/\/g02.a.alicdn.com\/kf\/HTB1Mq3WGXXXXXbSXFXXq6xXFXXXA\/201062613\/HTB1Mq3WGXXXXXbSXFXXq6xXFXXXA.jpg\" title=\"aeProduct.getSubject()\"\u003e\u003c\/p\u003e \n\u003cp\u003e 5. When Windows appears “Completing the Found New Hardware Wizard”, click “finish” to end setting up. \u003c\/p\u003e \n\u003cp\u003e   \u003c\/p\u003e \n\u003cp\u003e \u003cimg alt=\"aeProduct.getSubject()\" src=\"http:\/\/g03.a.alicdn.com\/kf\/HTB1Gdw0GXXXXXa4XpXXq6xXFXXXY\/201062613\/HTB1Gdw0GXXXXXa4XpXXq6xXFXXXY.jpg\" title=\"aeProduct.getSubject()\"\u003e\u003c\/p\u003e \n\u003cp\u003e 6. After setting up, please make sure the \"port (COM and LPT)\" of \"Start \\ Settings \\ Control Panel \\ system \\ hardware \\ Device Manager\" appears \"CP2101 USB to UART Bridge Controller(COMx)\". This COMx is the COM message of the USB programming cable. From then on, as long as you insert the programming cable, the COM port will appear. You just have to choose this COM port in application software such as programming software or communication software. \u003c\/p\u003e \n\u003cp\u003e   \u003c\/p\u003e \n\u003cp\u003e \u003cimg alt=\"aeProduct.getSubject()\" src=\"http:\/\/g01.a.alicdn.com\/kf\/HTB1Z9Q4GXXXXXa2XXXXq6xXFXXXy\/201062613\/HTB1Z9Q4GXXXXXa2XXXXq6xXFXXXy.jpg\" title=\"aeProduct.getSubject()\"\u003e\u003c\/p\u003e \n\u003cp\u003e The deletion of driver procedure \u003c\/p\u003e \n\u003cp\u003e   \u003c\/p\u003e \n\u003cp\u003e Deleting driver procedure is to discharge source of COM port so that other device can be used. When driver procedure has error, it should be deleted and reset up. Please delete the driver procedure as follows: \u003c\/p\u003e \n\u003cp\u003e 1. Unplug the USB programming cable from you PC. \u003c\/p\u003e \n\u003cp\u003e 2. Choose “USB Serial Converter Drivers”from \"Add or Delete Programs” in operation panel, and click the “Change\/Remove” button.  \u003cimg alt=\"aeProduct.getSubject()\" src=\"http:\/\/g02.a.alicdn.com\/kf\/HTB1puw0GXXXXXaEXpXXq6xXFXXX4\/201062613\/HTB1puw0GXXXXXaEXpXXq6xXFXXX4.jpg\" title=\"aeProduct.getSubject()\"\u003e\u003c\/p\u003e \n\u003cp\u003e How to change COM setting \u003c\/p\u003e \n\u003cp\u003e   \u003c\/p\u003e \n\u003cp\u003e 1. Delete the driver procedure of all USB to UART products to discharge COM port source, and reset up USB programming cable driver procedure. The device manager will display the cable address COM3. \u003c\/p\u003e \n\u003cp\u003e 2. In Windows 2000\/XP the COM slogan can be changed directly. Please double click COM port device that is need changing in the device manager, and the device attribute information window will appear. Choose “port setting” as the picture shows. Click \"Advanced\" button, and the advanced setting information window will appear. Set the COM port to the serial number you want and click \"OK\" button to complete. \u003c\/p\u003e \n\u003cp\u003e   \u003c\/p\u003e \n\u003cp\u003e \u003cimg alt=\"aeProduct.getSubject()\" src=\"http:\/\/g01.a.alicdn.com\/kf\/HTB1E_I3GXXXXXcgXXXXq6xXFXXXz\/201062613\/HTB1E_I3GXXXXXcgXXXXq6xXFXXXz.jpg\" title=\"aeProduct.getSubject()\"\u003e\u003cimg alt=\"aeProduct.getSubject()\" src=\"http:\/\/g03.a.alicdn.com\/kf\/HTB1bNM0GXXXXXaOXpXXq6xXFXXXC\/201062613\/HTB1bNM0GXXXXXaOXpXXq6xXFXXXC.jpg\" title=\"aeProduct.getSubject()\"\u003e\u003c\/p\u003e \n\u003cp\u003e Setting of RSLogix \u003c\/p\u003e \n\u003cp\u003e   \u003c\/p\u003e \n\u003cp\u003e After completing Driver installation, the corresponding COM port for the USB-1747-CP3 programming cable will be displayed in the “Device Manager” of Window. The step next is just to choose this COM port in the programming software and other application software and keep other communication parameters as in the Default settings. And the following steps are exactly the same as in the traditional programming cables with RS232 interfaces.  \u003c\/p\u003e \n\u003cp\u003e   \u003c\/p\u003e \n\u003cp\u003e \u003cimg alt=\"aeProduct.getSubject()\" src=\"http:\/\/g03.a.alicdn.com\/kf\/HTB1eZQ4GXXXXXbHXXXXq6xXFXXXn\/201062613\/HTB1eZQ4GXXXXXbHXXXXq6xXFXXXn.jpg\" title=\"aeProduct.getSubject()\"\u003e\u003c\/p\u003e \n\u003cp\u003e Notes and Troubleshoot \u003c\/p\u003e \n\u003cp\u003e   \u003c\/p\u003e \n\u003cp\u003e 1.  If the USB programming cable could not be detected when opening the PC, or some other outstanding issues occur, please replug it again.  \u003c\/p\u003e \n\u003cp\u003e   \u003c\/p\u003e \n\u003cp\u003e 2.  USB to UART is plug and play USB device. When data are being transmitted, please don’t disconnect it. \u003c\/p\u003e \n\u003cp\u003e   \u003c\/p\u003e \n\u003cp\u003e 1. Sometimes when Windows System failures or outstanding issues when plug or unplug the USB cable occur, please restart the computer and PLC. \u003c\/p\u003e \n\u003cp\u003e   \u003c\/p\u003e \n\u003cp\u003e 2. If the COM port with “*” symbol in the software,such as “*COM3”,it indicates this COM port is at fault,pls exit programming software and then replug the USB port or reinstall the USB driver. \u003c\/p\u003e \n\u003cp\u003e \u003cbr\u003e Rejection provision \u003c\/p\u003e \n\u003cp\u003e   \u003c\/p\u003e \n\u003cp\u003e This document is to provide information, and the contents will not be noticed when revising. Because of the direct or indirect loss or errors caused by revised document, will not be the responsibility of the manufacturer. \u003c\/p\u003e \n\u003cp\u003e   \u003c\/p\u003e \n\u003cp\u003e   \u003c\/p\u003e","brand":"NewTouchBuff Official Store","offers":[{"title":"Default Title","offer_id":49582588330280,"sku":"USB-1747-CP3","price":18.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0764\/3024\/6184\/files\/HTB1wsxLIXXXXXXRXXXXq6xXFXXXb.jpg?v=1733200360","url":"https:\/\/newtouchbuff.com\/uz\/products\/hot-sales-usb-1747-cp3-usb-adapter-for-ab-slc-5-03-5-04-5-05-plc-free-shipping","provider":"NewTouchBuff Official Store","version":"1.0","type":"link"}